Evaluation of translucent insulating materials for roofs in shopping centers

Keywords: Translucent Insulating Materials, Aerogel, experimental models, thermal analysis, light analysis

Abstract

The translucent insulating materials used in roofs of large clearing and curved structure, have the potential to reduce energy consumption by approximately 20 to 30 percent. They are also considered an energy saving strategy in buildings that allocate energy consumption to systems for thermal and visual comfort. This study proposed to develop an experimental method to analyze the thermal, light and relative humidity behavior of two unconventional materials (aerogel and polytetrafluoroethylene (PTFE)) and a comparative element (polyvinyl chloride (PVC)) in three type modules, located in the ZMCM.  The exchange rate, gain and average illuminance were evaluated with the aim of identifying the most energy-efficient material.  The PTFE presented the highest illuminance values, based on the results of the data analysis, during the three types of sky in summer (or hot-humid season) with an average difference of 3 296.80 lux with respect to PVC.

Downloads

Download data is not yet available.

References

Aerogel Technologies. (2004). BuyAerogel.com | Planet Earth’s Source for AerogelTM. http://www.buyaerogel.com/

Alison Aerogel. (2009). Guangdong Alison High-tech Co., Ltd. https://www.ydalison.com/EN/

Alonso, L., Bedoya, C., Lauret, B., & Alonso, F. (2013, febrero). F2 TE3 : sistema de cerramiento transparente, ligero, de altas prestaciones energéticas que permite el diseño con formas libres F 2 TE 3 : Free-Form Transparent Energy Efficient Envelope. Informes de la Construcción, 65, 443-456. https://doi.org/10.3989/ic.12.068

Atawa H, M., Al-Kattan, A., & Elwan, A. (2015). Research Article Towards Nano Architecture : Nanomaterial in Architecture - a Review of Functions and Applications. International Journal of Recent Scientific Research, 6(4), 3551-3564. http://www.recentscientific.com

Benítez, R. S. (2017). DISEÑO Y CARACTERIZACIÓN DE ESPACIOS EXPERIMENTALES MÓDULO DE EXPERIMENTACIÓN DEL PROGRAMA DE MAESTRÍA Y DOCTORADO EN ARQUITECTURA. UNAM.

Birdair. (2014). Insulated Tensioned Membrane. Tensile Architectural Structures, 4. www.birdair.com

Buratti, C., & Moretti, E. (2011a). Lighting and Energetic Characteristics of Transparent Insulating Materials: Experimental Data and Calculation. Indoor Built Environ, 20(4), 400-411. https://doi.org/10.1177/1420326X11409470

Buratti, C., & Moretti, E. (2011b). Transparent insulating materials for buildings energy saving: experimental results and performance evaluation. Third International Conference on Applied Energy, May, 1421-1432.

Buratti, C., & Moretti, E. (2012). Experimental performance evaluation of aerogel glazing systems. Applied Energy, 97, 430-437. https://doi.org/10.1016/j.apenergy.2011.12.055

Casini, M. (2016). Advanced insulating materials. En Smart Buildings. New York: Springer-Verlag. https://doi.org/10.1016/b978-0-08-100635-1.00004-6

Cerdá Talón, M. (2019). Membranas para estructuras superficiales tensadas. Universidad Politecnica de Valencia.

Chatellier Lorentzen, D., & McNeil, M. (2019). Consumo de electricidad de edificios no residenciales en México: la importancia del sector de servicios. Cuaderno de la CONUEE, 3(1), 13. https://www.gob.mx/cms/uploads/attachment/file/455552/cuaderno3nvociclo_2.pdf

Chen, Y., Xiao, Y., Zheng, S., Liu, Y., & Li, Y. (2018). Dynamic heat transfer model and applicability evaluation of aerogel glazing system in various climates of China. Energy, 163, 1115-1124. https://doi.org/10.1016/j.energy.2018.08.158

Comité Español de Iluminación (CEI), Instituto para la Diversificación y Ahorro de la Energía (IDAE), & Consejo Superior de los Colegios de Arquitectos de España (CSCAE). (2005, mayo). Guía técnica para el aprovechamiento de la luz natural en la iluminación de edificios. Informes IDAE, 1, 177. www.idae.es

Cuce, E., Cuce, P. M., Wood, C. J., & Riffat, S. B. (2014). Toward aerogel based thermal superinsulation in buildings: A comprehensive review. En Renewable and Sustainable Energy Reviews (Vol. 34, pp. 273-299). Elsevier Ltd. https://doi.org/10.1016/j.rser.2014.03.017

Dowson, M., Harrison, D., Craig, S., & Gill, Z. (2011). Improving the thermal performance of single-glazed windows using translucent granular aerogel. International Journal of Sustainable Engineering, 4(3), 266-280. https://doi.org/10.1080/19397038.2011.558931

Edificios de México. (2020, abril 1). Centros comerciales que cerraron sus puertas por la emergencia sanitaria. Edificios de México. https://www.edemx.com/site/2020/04/01/centros-comerciales-que-cerraron-sus-puertas-por-la-emergencia-sanitaria/

Fenercom. (2012). Guía sobre Materiales Aislantes y Eficiencia Energética. https://www.fenercom.com/publicacion/guia-sobre-materiales-aislantes-y-eficiencia-energetica-2012/

Guillén Guillén, C. A., Muciño Vélez, A., Santa Ana Lozada, P., & Verduzco Chirino, G. (2018). Análisis de las propiedades térmicas del Arundo Donax (carrizo) y Zea Mays (caña maíz) para su uso como material aislante de cubiertas. Academia XXII, 9(18), 90. https://doi.org/10.22201/fa.2007252xp.2018.18.67947

Hegazy, I. R. (2019). Toward energy-efficient governmental buildings in Egypt: Investigating the impact of nano aerogel glazing on energy performance. International Journal of Low-Carbon Technologies, 15(1), 17-24. https://doi.org/10.1093/ijlct/ctz052

Instituto de Ciencias de la Atmósfera y Cambio Climático, U. (2009, enero 21). Atlas Climático Digital de México. Atlas Climático Digital de México. http://uniatmos.atmosfera.unam.mx:8080/ACDM/servmapas

Kistler, S. S. (1931). Coherent Expanded Aerogels and Jellies. Nature 1931 127:3211, 127(3211), 741-741. https://doi.org/10.1038/127741a0

Kneifel, J. (2010). Life-cycle carbon and cost analysis of energy efficiency measures in new commercial buildings. Energy and Buildings, 42(3), 333-340. https://doi.org/10.1016/j.enbuild.2009.09.011

Lechner, N. (2015). Heating, cooling, lighting: Sustainable design methods for architects (4.a ed.). John Wiley & Sons, Inc., Hoboken, New Jersey. https://www.wiley.com/en-mx/9781118582428

Liliana G. Torres Fernández. (2010, abril 12). Instrumentos de medición. Slideshare. https://es.slideshare.net/liliagtorres/instrumentos-de-medicin-3705238

Lizan, J., & En Nuestro País. (2018). Centros Comerciales, fenómeno urbano que se afianza en México. El economista Valores y Dinero, 1-2. www.atkearney.com.mx

Lonas Lorenzo. (2017). Big Span structure. Lonas Lorenzo. https://lonaslorenzo.com.mx/productos/

Molina, C. G. (2011). Alternativas para la mejora de la eficiencia energética de los acristalamientos: los vidrios dinámicos. Universidad Politécnica de Madrid, Madrid, 387.

Navarrete, F. (2019, octubre 23). Destaca México por mayor afluencia en centros comerciales. Centrourbano Inmobiliario. https://centrourbano.com/2019/08/23/destaca-mexico-mayor-afluencia-centros-comerciales/

Noticias, fotografías y videos de tu P. M. (2013). Manuel Castro Romero Tercer Informe de Gobierno. Municipio de Tepechitlán Zacatecas H. Ayuntamiento 2010-2013. https://tepechitlan.wordpress.com/

Reim, M., Körner, W., Manara, J., Korder, S., Arduini-Schuster, M., Ebert, H. P., & Fricke, J. (2005). Silica aerogel granulate material for thermal insulation and daylighting. Solar Energy, 79(2), 131-139. https://doi.org/10.1016/j.solener.2004.08.032

Riffat, S. B., & Qiu, G. (2013). A review of state-of-the-art aerogel applications in buildings. International Journal of Low-Carbon Technologies, 8(April 2012), 1-6. https://doi.org/10.1093/ijlct/cts001

Rodríguez-Muñoz, N. A., Nájera-Trejo, M., & Martín-Domínguez, I. R. (2018). Análisis del desempeño térmico de los sistemas constructivos de un edificio de oficinas mediante simulaciones dinámicas. Ingeniería, investigación y tecnología, 19(3), 281-291. https://doi.org/10.22201/fi.25940732e.2018.19n3.024

Santillana Ramos, C. (2018). Lo que gasta un centro comercial. Energy Management Magazine, 25. https://issuu.com/puntualmedia/docs/re_web_nov_dic-compressed

Schultz, J. M., Jensen, K. I., & Kristiansen, F. H. (2005). Super insulating aerogel glazing. Solar Energy Materials and Solar Cells, 89(2-3), 275-285. https://doi.org/10.1016/j.solmat.2005.01.016

Sun, Y., Wilson, R., & Wu, Y. (2018). A Review of Transparent Insulation Material (TIM) for building energy saving and daylight comfort. Applied Energy, 226, 713-729. https://doi.org/10.1016/j.apenergy.2018.05.094

TES POWER. (2019). Centros Comerciales y energía eficiente. TES POWER. https://tespower.com.mx/centros-comerciales-y-energia-eficiente/

Tinsa México. (2020). Mall Analytics | Plazas Comerciales. Passion For Data. http://www.plazascomerciales.com.mx/mall-analytics/

Torres Casique, J. L. (2017). El Club de Roma, aportes para el desarrollo. Una historiografía de su obra publicada. Trienal de investigación FAU UCV, 1-15. http://trienal.fau.ucv.ve

Wong, I. L., Eames, P. C., & Perera, R. S. (2007). A review of transparent insulation systems and the evaluation of payback period for building applications. En Solar Energy (Vol. 81, Número 9, pp. 1058-1071). Pergamon. https://doi.org/10.1016/j.solener.2007.04.004

Xunta de Galicia. (2017). Estado del Arte de Materiales Inteligentes. Oportunidades Industria 4.0 en Galicia.

Published
2022-06-24
How to Cite