Edificios de concreto reforzado con piso suave en planta baja

  • Cutberto Rodríguez Álvarez Universidad Autónoma del Estado de Hidalgo
  • Roberto Pérez Martínez Universidad Autónoma de Nuevo León
  • Humberto Iván Navarro Gómez Universidad Autónoma del Estado de Hidalgo
Keywords: Masonry walls, soft story in the first floor, reliability.

Abstract

This paper studies the contribution to stiffness and strength of the masonry walls in reinforced concrete buildings against seisms. Studies of strong earthquakes that occurred in the past 150 years in various parts of the world have identified that a significant number of collapsed or damaged structural systems were of the type “soft or weak story”. Currently, some countries located in areas of seismic risk have adopted within their building systems orthogonal-framed structures made of reinforced concrete and that employ masonry infill walls in buildings up to 6 levels of height. These panels are considered nonstructural components and therefore they are rarely included in the structural analysis; nevertheless, the presence of walls increases considerably the strength and stiffness, changes the dynamic characteristics and affects the global response of the structure.

Downloads

Download data is not yet available.

References

Aguilar, G. Alcocer, S. M. (2001) Efecto del refuerzo horizontal en el comportamiento de muros de mampostería confinada ante cargas laterales. Informes técnicos, Coordinación de Investigación, Área de Ingeniería Estructural y Geotecnia, CENAPRED, México D. F.

Alamilla, J. (2001) Criterios de diseño sísmico basados en confiabilidad de estructuras aporticadas. Tesis doctoral, Posgrado en Ingeniería, UNAM, México D. F.

Bazán, E., Meli, R. (2004) Diseño Sísmico de Edificios. Limusa-Noriega, México.

Carrillo, J., González, G. (2007) Influencia de la mampostería no reforzada en el comportamiento inelástico de pórticos de concreto. Dyna, 74(152), 217-227.

Chopra, A. K., Clough, D. P., Clough, R. W. (1972) Earthquake resistance of buildings with a ‘soft’ first storey. Earthquake Engineering and Structural Dynamics, 1(4), 347-355.

Comisión Federal de Electricidad (1993) Manual de Diseño de Obras Civiles, Diseño por Sismos. México, D. F.

Cornell, C. (1969) A Probability-Based Structural Code. ACI Journal, 66(12), 974-985.

Díaz, J. L. (2008) Criterios de aceptación para el diseño sísmico por desempeño y confiabilidad de edificios de concreto reforzado, con piso suave en planta baja, desplantados en suelos blandos de la ciudad de México. Tesis de maestría, Posgrado en Ingeniería, UNAM, México D. F.

Gobierno del Distrito Federal (2004) Normas Técnicas Complementarias. México, D. F.

Kadysiewski, S., Mosalam, K.M. (2009) Modeling of Unreinforced Masonry Infill Walls Considering In-Plane and Out-of-Plane Interaction. Technical Report. Centro de Investigaciones de Ingeniería Sísmica del Pacifico (PEER), Berkeley, California. PEER Report 2008/102.

Kasim, K., Fuat, D., Mustafa, S. (2007) Earth Assesment of R/C Structures with Masonry Infill Walls. International Journal of Science and Technology, 2(2), 155-164.

Mazzoni, S., Mckenna, F., Scott M. H., Fenves G. L., et al. (2007) OpenSees Command Language Manual. Centro de Investigaciones de Ingeniería Sísmica del Pacifico (PEER), Berkeley, California.

Olusola, J. (2008) Comportamiento de muros de mampostería: Calibración de un modelo no lineal de elementos finitos utilizando OpenSees. Tesis de maestría. Escuela Superior de Ingeniería y Arquitectura, Unidad Zacatenco, Sección de Estudios de Posgrado e Investigación, México D. F.

Paulay T., Priestley, M. J. N. (1992) Seismic Design of Reinforced Concrete and Masonry Buildings. Volume 1. Wiley, Nueva York.

Pérez, R. (2010) Confiabilidad y optimización para diseño sísmico de edificios considerando la contribución de muros de mampostería. Tesis doctoral, Posgrado en Ingeniería, UNAM, México D.F.

Rangel, J., Esteva, L. (2013) Simulation of buildings. Instituto de Ingeniería, Sección de Mecánica Aplicada de la Universidad Nacional Autónoma de México (UNAM) y Escuela de Ingeniería de la Universidad Veracruzana, campus Ciudad Mendoza.

Rathbun, J. C. (1938) Wind forces on a tall building. Proceedings of the American Society of Civil Engineers, 64, 1335-1375.

Reza, M., Azad, A., Akbar, A. (2012) Seismic Behavior and Retrofit of Infilled Frames. En: Earthquake-Resistant Structures - Design, Assessment and Rehabilitation (Moustafa A., Ed.), InTech, DOI: 10.5772/28579 [en línea]. http://www.intechopen.com/books/earthquake-resistant-structures-design-assessment-and-rehabilitation/seismic-design-and-retrofit-of-infilled-frames

Ripley, F. (1932) Earthquake damage and earthquake insurance. McGraw-Hill, Nueva York

Ruiz, S. E., Diederich, R. (1989) The Mexico Earthquake of September 19, 1985 – The Seismic Performance of Buildings with Weak First Storey. Earthquake Spectra, 5(1), 89-102.
Published
2016-07-05
How to Cite
Rodríguez Álvarez, C., Pérez Martínez, R., & Navarro Gómez, H. I. (2016). Edificios de concreto reforzado con piso suave en planta baja. Pädi Boletín Científico De Ciencias Básicas E Ingenierías Del ICBI, 4(7). https://doi.org/10.29057/icbi.v4i7.487